Skip to search boxSkip to navigationSkip to main content

Registration of physical space to laparoscopic image space for use in minimally invasive hepatic surgery

  • J. D. Stefansic(corresponding author)
    ,
  • A. J. Herline
    ,
  • Y. Shyr
    ,
  • W. C. Chapman
    ,
  • J. M. Fitzpatrick
    ,
  • B. M. Dawant
*Corresponding author for this work
Scholary Output:
Chapter in Book/Report/Conference proceeding
Conference contribution

Related Event

Title

5th IEEE EMBS International Summer School on Biomedical Imaging, SSBI 2002

Event type

Other

Date

06/15/2002 - 06/23/2002

Location

Berder IslandFrance

Abstract

While laparoscopes are used for numerous minimally invasive (MI) procedures, MI liver resection and ablative surgery is infrequently performed. The paucity of cases is due to the restriction of the field of view by the laparoscope and the difficulty in determining tumor location and margins under video guidance. By merging MI surgery with interactive, image-guided surgery (ITGS), we hope to overcome localization difficulties present in laparoscopic liver procedures. One key component of any DGS system is the development of accurate registration techniques to map image space to physical or patient space. This manuscript focuses on the accuracy and analysis of the direct linear transformation (DLT) method to register physical space with laparoscopic image space on both distorted and distortion-corrected video images. Experiments were conducted on a liver-sized plastic phantom affixed with 20 markers at various depths. After localizing the points in both physical and laparoscopic image space, registration accuracy was assessed for different combinations and numbers of control points (n) to determine the quantity necessary to develop a robust registration matrix. For n = 11, average target registration error (TRE) was 0.70 ± 0.20 mm. We also studied the effects of distortion correction on registration accuracy. For the particular distortion correction method and laparoscope used in our experiments, there was no statistical significance between physical to image registration error for distorted and corrected images. In cases where a minimum number of control points (n = 6) are acquired, the DLT is often not stable and the mathematical process can lead to high TRE values. Mathematical filters developed through the analysis of the DLT were used to prospectively eliminate outlier cases where the TRE was high. For n = 6, prefilter average TRE was 17.4 ± 153 mm for all trials; when the filters were applied, average TRE decreased to 1.64 ± 1.10 mm for the remaining trials.

Publication Information

Output type

Scholary Output:
Chapter in Book/Report/Conference proceeding
Conference contribution

Original language

English (US)

Article number

1233999

Publication milestones

  • Published - 01/01/2002

Publication status

Published - 01/01/2002

Publisher

Institute of Electrical and Electronics Engineers Inc.

Publication series

  • Publication series name: Biomedical Imaging V - Proceedings of the 5th IEEE EMBS International Summer School on Biomedical Imaging, SSBI 2002

ISBN (Electronic)

0780375076, 9780780375079

Publication IDs

  • Scopus: 84963491229

Host publication title

Biomedical Imaging V - Proceedings of the 5th IEEE EMBS International Summer School on Biomedical Imaging, SSBI 2002

Host publication editors

  • Christian Roux
  • Jean-Louis Coatrieux

Publication metrics

Metrics

SciVal
citations
2
Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1
SciVal
Author count
7
Scopus
citations

PlumX, opens in new tab

Captures
4
Citation count
1

Funding Details

This work was supported in part by the National Institute of Health (NIH) under Grants NIGMS GM52798 and NRSA #1 F32 DK 09671-01 SB and NSF Grant BES-9703714.