Relative accuracy of four removable die systems
- Michael Myers,
- John H. Hembree(corresponding author)
- Medical University of South Carolina
Scholary Output:
Contribution to journal
Article
Peer-reviewOpen access
Abstract
Four removable die systems were studied: brass dowel pins, the Plastipin, the J-Pin, and the Logix Model System. Results of measurements made of 10 working casts to determine the amount and type of vertical and horizontal shift revealed no statistical significance between various dies.
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 163-165 (3 pages)Journal (Volume, Issue Number)
The Journal of Prosthetic Dentistry (Volume 48, Issue 2)Publication milestones
- Published - 08/1982
Publication status
Published - 08/1982
ISSN
0022-3913Publication IDs
- Scopus: 0020171711
- PubMed: 7050360
Publication metrics
Metrics
Fractional count
1
Fractional count
0.50
Fractional count
1
Fractional count
0.50
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Captures
14
Citation count
13