Skip to search boxSkip to navigationSkip to main content

Retrospective Analysis of 12 Months Glaucoma Implant Efficacy: XEN45 and PreserFlo Microshunt

  • Giulia Saletta
    ,
  • Antonios Alexoudis
    ,
  • Zisis Gkatzioufas
    ,
  • Matthias Grieshaber
    ,
  • Anthia Papazoglou
    ,
  • Markus Tschopp
*Corresponding author for this work
  • University of Basel
    ,
  • Cantonal Hospital Aarau
    ,
  • University of Zurich
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Abstract

Purpose Several new implant devices have recently been introduced to glaucoma surgery using various techniques for reducing intraocular pressure (IOP). Two implants introduced during the past couple of years, XEN45 and PreserFlo Microshunt, are both designed to control subconjunctival filtration. There are two Swiss multicenter studies that collected the data retrospectively to analyze the efficacy and safety of these two devices separately. In this study, we report the analysis of the combined data subset from the University Hospital of Basel. Subjects and Methods The XEN45 implantation technique was introduced to Basel University Hospital in 2016 and PreserFlo Microshunt in 2018. Sixty operated patients, thirty in each group, were operated on by one surgeon, clinically followed up, and their data retrospectively analyzed from medical records. Only standalone procedures, without combined phacoemulsification, were considered in this analysis; the lens status, however, was neither an inclusion nor an exclusion criterion. Further inclusion criteria were the diagnosis of open-angle glaucoma, no previous glaucoma surgery, other than laser trabeculoplasty, and complete medical records during the 12 months of follow-up. IOP reduction during a 12-month postoperative period was the primary outcome measure as well as the number of IOP reducing drugs. The number of subsequent surgical interventions and complications/adverse events are descriptively reported. Results Patient age, gender, ophthalmological diagnosis, and initial preoperative IOP were well balanced between the two groups. Postoperative IOP course was comparable between the two methods for the first 12 months. IOP measurements were taken preoperatively and then on the first postop day, week 1, month 1, and months 3, 6, and 12 for the PreserFlo Microshunt vs. XEN45 (mmHg): 23.6 vs. 24.9, 9.0 vs. 8.9, 11.4 vs. 10.6, 13.0 vs.18.3, 16.8 vs.15.1, 15.9 vs.15.0, and 15.4 vs.14.5, respectively. IOP reducing medications were also comparable between the two groups. The study showed that subsequent interventions were more frequent in the XEN45 (13) than in the PreserFlo Microshunt group (7). Conclusion Both methods demonstrate satisfactory IOP control within a 12-month postoperative period with practically no serious adverse events/complications, but with relatively high numbers of subsequent interventions (needlings), particularly in the XEN45 group.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 429-434 (6 pages)

Journal (Volume, Issue Number)

Klinische Monatsblatter fur Augenheilkunde (Volume 239, Issue 4)

Publication milestones

  • Published - 04/26/2022

Publication status

Published - 04/26/2022

ISSN

0023-2165

Publication IDs

  • Scopus: 85128879107
  • PubMed: 35472784

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
21
Citation count
6