Skip to search boxSkip to navigationSkip to main content

Separating bedtime rest from activity using waist or wrist-worn accelerometers in youth

  • ,
  • Zhiyi Xu
    ,
  • Leena Choi
    ,
  • Sari Acra
    ,
  • Kong Y. Chen
    ,
  • Maciej S. Buchowski
  • Vanderbilt University
    ,
  • National Institutes of Health
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Open access

Abstract

Recent interest in sedentary behavior and technological advances expanded use of watch-size accelerometers for continuous monitoring of physical activity (PA) over extended periods (e.g., 24 h/day for 1 week) in studies conducted in natural living environment. This approach necessitates the development of new methods separating bedtime rest and activity periods from the accelerometer recordings. The goal of this study was to develop a decision tree with acceptable accuracy for separating bedtime rest from activity in youth using accelerometer placed on waist or wrist. Minute-by-minute accelerometry data were collected from 81 youth (10-18 years old, 47 females) during a monitored 24-h stay in a wholeroom indirect calorimeter equipped with a force platform covering the floor to detect movement. Receiver Operating Characteristic (ROC) curve analysis was used to determine the accelerometer cut points for rest and activity. To examine the classification differences, the accelerometer bedtime rest and activity classified by the algorithm in the development group (n = 41) were compared with actual bedtime rest and activity classification obtained from the room calorimeter-measured metabolic rate and movement data. The selected optimal bedtime rest cut points were 20 and 250 counts/min for the waistand the wrist-worn accelerometer, respectively. The selected optimal activity cut points were 500 and 3,000 counts/min for waist and wrist-worn accelerometers, respectively. Bedtime rest and activity were correctly classified by the algorithm in the validation group (n = 40) by both waist- (sensitivity: 0.983, specificity: 0.946, area under ROC curve: 0. 872) and wrist-worn (0.999, 0.980 and 0.943) accelerometers. The decision tree classified bedtime rest correctly with higher accuracy than commonly used automated algorithm for both waist- and wrist-warn accelerometer (all p,0.001). We concluded that cut points developed and validated for waist- and wrist-worn uniaxial accelerometer have a good power for accurate separation of time spent in bedtime rest from activity in youth.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Article number

e92512

Journal (Volume, Issue Number)

PloS one (Volume 9, Issue 4)

Publication milestones

  • Published - 04/11/2014

Publication status

Published - 04/11/2014

ISSN

1932-6203

Publication IDs

  • Scopus: 84899641255
  • PubMed: 24727999

Publication metrics

Metrics

Fractional count
1
Fractional count
0.17
Fractional count
5
Fractional count
0.83
Fractional count
1
Fractional count
1
Scopus
citations

PlumX, opens in new tab

Citation count
28
Captures
104

Funding Details

FundersFunding number
National Center for Advancing Translational Sciences
-
National Institutes of Health
-
NHLBI
R01HL082988