Skip to search boxSkip to navigationSkip to main content

Short-term preservation of autogenous vein grafts: Effectiveness of University of Wisconsin solution

  • Nicola Cavallari(corresponding author)
    ,
  • Worku Abebe
    ,
  • Andrea Mingoli
    ,
  • Paolo Sapienza
    ,
  • William J. Hunter
    ,
  • Devendra K. Agrawal
*Corresponding author for this work
  • Unknown
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Background. Suboptimal preservation of autologous veins in storage solutions causes endothelial cell damage that can contribute to graft failure. The purpose of this study was to compare the effects of short-term storage of veins in autologous whole blood (AWB), 0.9% normal saline solution (NS), and University of Wisconsin solution (UWs) on vein structure and function after grafting. Methods. Autogenous jugular and femoral veins were atraumatically harvested from mongrel dogs. One vein segment was immediately implanted to serve as a control, and the other segments were stored for 45 minutes in AWB, NS, or UWs. The veins were implanted as reversed interposition graft in the carotid or femoral arteries. After 6 weeks light and scanning electron microscopy and isometric tension studies were performed on explanted vein grafts. Results. Morphologic studies revealed an intact endothelium that stained positively for factor VIII. Intimal thickness was similar between controls (42 ± 12 μm) and veins stored in UWs (53 ± 8 μm) (p = not significant), but it was significantly increased in veins stored in AWB (151 ± 29 μm) and NS (149 ± 18 μm) (p < 0.05). Sensitivity and maximum contraction to norepinephrine were not altered in veins preserved in UWs (6.0 ± 0.1 μmol/L and 0.19 ± gm/mm2) but were significantly reduced (p < 0.05) in those stored in AWB (7.2 ± 0.1 μmol/L and 0.08 ± 0.02 gm/mm2) and NS (7.0 ± 0.3 μmol/L and 0.09 ± 0.02 gm/mm2) compared with controls (5.9 ± 0.2 μmol/L and 0.20 ± 0.02 gm/mm2). The sensitivity and maximum relaxation to acetylcholine and sodium nitroprusside of veins preserved in AWB, NS and UWs were similar to controls (p = not significant). Conclusions. Vein storage in UWs preserves smooth muscle cell function compared with veins stored in NS or AWB. Therefore UWs is a more suitable medium for short-term preservation of veins in cardiovascular operation.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 64-71 (8 pages)

Journal (Volume, Issue Number)

Surgery (Volume 121, Issue 1)

Publication milestones

  • Published - 01/1997

Publication status

Published - 01/1997

ISSN

0039-6060

Publication IDs

  • Scopus: 0031021155
  • PubMed: 9001553

Publication metrics

Metrics

SciVal
Author count
8
SciVal
citations
14
SciVal
Paper percentile
65
Scopus
citations
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Citation count
15
Captures
11