Skip to search boxSkip to navigationSkip to main content

Subtenon's depot corticosteroid injections in patients with a history of corticosteroid-induced intraocular pressure elevation

  • Darrin S. Levin
    ,
  • Dennis P. Han(corresponding author)
    ,
  • Sundeep Dev
    ,
  • William J. Wirostko
    ,
  • William F. Mieler
    ,
  • Thomas B. Connor
*Corresponding author for this work
  • Medical College of Wisconsin
Scholary Output:
Contribution to journal
Article
Peer-review

Open access

Abstract

PURPOSE: To determine whether a history of intraocular pressure elevation from local corticosteroid administration could predict subsequent intraocular pressure elevation after posterior subtenon's corticosteroid injection. METHODS: A retrospective review was performed of 64 consecutive patients (64 eyes) receiving posterior subtenon's corticosteroid injection. Patients were categorized as either historical corticosteroid responders or nonresponders based on intraocular pressure response to topical corticosteroid drops in the same eye or to previous posterior subtenon's corticosteroid injection of the fellow eye. Historical responders were defined as having a relative intraocular pressure increase of 5 mm Hg and absolute intraocular pressure greater than 24 mm Hg with an anatomically open angle. Relative risk of intraocular pressure elevation was evaluated based on historical response and presenting diagnosis. RESULTS: Nine eyes were historical responders, and 55 eyes were historical nonresponders. A higher rate of recurrent intraocular pressure elevation developed in historical responder eyes (4 of 9, 44%) compared with nonresponders (7 of 55, 13%) after posterior subtenon's injection (P = .04, Fisher's test; P = .07, Kaplan-Meier analysis). Historical responders with uveitis were at significantly higher risk of intraocular pressure elevation than nonresponders without uveitis (hazard ratio = 10.8, P = .04, Cox proportional hazards). All but one eye that developed intraocular pressure elevation from posterior subtenon's injection was adequately controlled with topical antiglaucoma therapy. CONCLUSION: In nonglaucomatous eyes, a previous history of corticosteroid-induced intraocular pressure elevation is a relative, not absolute, contraindication to posterior subtenon's corticosteroid injection, because the risk of intraocular pressure elevation is not absolute, and because it can usually be well controlled with topical antiglaucoma therapy.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 196-202 (7 pages)

Journal (Volume, Issue Number)

American Journal of Ophthalmology (Volume 133, Issue 2)

Publication milestones

  • Published - 2002

Publication status

Published - 2002

ISSN

0002-9394

Publication IDs

  • Scopus: 0036141498
  • PubMed: 11812422

Publication metrics

Metrics

SciVal
citations
42
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1
Scopus
citations
SciVal
FWCI
2.98
SciVal
Author count
8
SciVal
Paper percentile
83

PlumX, opens in new tab

Captures
19
Citation count
50

Funding Details

Dr Dev is a 1998–1999 AOS-Knapp, and R.G. Michels Fellow. Dr Wirostko is a 1998–1999 Heed Fellow. This work is supported in part by the Thomas M. Aaberg Retina Research Fund, Milwaukee, Wisconsin, by an unrestricted grant from Research to Prevent Blindness, Inc, New York, New York, and by National Eye Institute core grant EY01931, Bethesda, Maryland.