SU‐GG‐J‐30: A Novel Scatter Reduction and Correction Method to Improve Cone‐Beam CT (CBCT) Image Quality

  • L. Ren
    ,
  • J. Kim
    ,
  • Q. Liu
    ,
  • B. Movsas
    ,
  • I. Chetty
    ,
  • J. Jin
  • Henry Ford Health System
    ,
  • Wayne State University
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Purpose: To develop a novel scatter reduction and correction method to improve the CBCT image quality for IGRT applications. Method and Materials: A one‐dimensional grid composed of lead with equal interspacing was positioned between the x‐ray source and the imaging object during CBCT acquisition. The grid provides direct scatter reduction by blocking half of the beams. Partial image data were obtained from the grid inter‐space (unblocked) region while scatter was measured from the blocked region beneath the grid in the projection images. Scatter was corrected by subtracting the measured scatter from the original projection image. Information in the penumbra region of each grid septa was derived. Three modes were developed to reconstruct full CBCT images from partially blocked projections. In single rotation axial mode, interpolation was used to fill in the missing data in the half‐fan projections. In dual rotation mode, two‐rotation half‐fan scans were acquired with the grid offset by half a grid cycle, and complimentary projections were merged to form complete projections for reconstruction. In single rotation helical mode, one‐rotation full‐fan scan was acquired with the grid offset by half a grid cycle at the scan center. Both CatPhan and anthropomorphic pelvis phantoms were used to evaluate the method. Results: In the CatPhan study, CNR was improved using our approach from 4.3 to 6.4 in comparison to conventional CBCT, and CT‐number linearity correlation coefficient increased from 0.88 to 0.998. Scatter induced streak artifacts were significantly reduced. In the pelvis phantom study, complete sets of CBCT images were reconstructed and scatter related artifacts were significantly reduced in all three modes. Conclusion: Our method enhances CNR and provides much more accurate measurement of scatter with reduced or equivalent dose to conventional CBCT. Scatter‐related artifacts are substantially reduced, and the CBCT images generated are of appropriate quality for adaptive radiation therapy.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Page 3151 (1 page)

Journal (Volume, Issue Number)

Medical Physics (Volume 37, Issue 6)

Publication milestones

  • Published - 06/2010

Publication status

Published - 06/2010

ISSN

0094-2405

Publication IDs

  • Scopus: 85024775130

Publication metrics

Metrics

SciVal
Author count
6
SciVal
Paper percentile
24
Fractional count
1
Fractional count
0.17
Fractional count
5
Fractional count
0.83
Fractional count
1
Fractional count
1