Abstract

The purpose of this study was to compare the tensile adhesive fatigue behavior of 2 composite adhesives used in the resin-bonded bridge technique to both enamel and a base metal alloy. Samples were tested to failure or to a maximum of 106 cycles. The practical endurance limit for both was determined and the fracture surfaces were evaluated using SEM. The nature of the fatigue failure of the 2 cements varied. The higher viscosity cement exhibited failure primarily due to tag pull out from the etched enamel. This occurred at significantly lower load levels as compared to the lower viscosity cement. The lower viscosity cement exhibited both adhesive and cohesive failure at higher load levels. The majority of fatigue failures in the lower viscosity material occurred at the composite/bonding agent interface or through the material itself.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 163-168 (6 pages)

Journal (Volume, Issue Number)

Dental Materials (Volume 4, Issue 3)

Publication milestones

  • Published - 06/1988

Publication status

Published - 06/1988

ISSN

0109-5641

Publication IDs

  • Scopus: 0024020863
  • PubMed: 3268484

Publication metrics

Metrics

Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1
Scopus
citations

PlumX, opens in new tab

Captures
4
Citation count
16