Skip to search boxSkip to navigationSkip to main content

The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading

  • Stephen M. Cameron(corresponding author)
    ,
  • W. Jack Morris
    ,
  • Stephen M. Keesee
    ,
  • Todd B. Barsky
    ,
  • M. Harry Parker
*Corresponding author for this work
  • US Army Dental Activity
    ,
  • Augusta University
    ,
  • US Army Dental Activity
    ,
  • US Army Dental Activity
    ,
  • Department of Veteran Affairs Medical Center
Scholary Output:
Contribution to journal
Article
Peer-review

Open access

Abstract

Statement of problem: Clinicians have used resistance form as a basis for determining guidelines for preparation design to ensure clinical success of cemented cast restorations. Disagreement on whether clinical success follows the on-off or linear nature of resistance form continues. Purpose: The purpose of this study was to evaluate the number of cycles required to dislodge a cemented complete crown casting under a cyclic lateral load as a function of taper and to compare this relationship for the resistive and nonresistive ranges of taper. Material and methods: Three dies were milled from stainless steel at each of the following tapers: 4, 8, 12, 16, 20, 24, 28, and 32 degrees. A gold-palladium metal-ceramic alloy crown was fabricated for each die, cemented, and subjected to lateral cyclic loading until failure or 1,000,000 cycles. The limiting taper for the dies with their given height and base was 26.6 degrees. Dies with taper less than 26.6 degrees had resistance form, whereas dies with taper larger than 26.6 degrees did not. A linear regression (α=.05) was used to evaluate the relation of cycles at dislodgement to taper. Results: The average number of cycles to crown dislodgement or completion for each taper (SD), in units of 10,000, was as follows: 4 degrees, 100 (0); 8 degrees, 100 (0); 12 degrees, 93.54 (16.56); 16 degrees, 61.33 (38.47); 20 degrees, 25.73 (34.67); 24 degrees, 4.33 (7.36); 28 degrees, 0.06 (0.08); and 32 degrees, 0.05 (0.09). The crowns in the resistive area less than 26.6 degrees that demonstrated failure showed a linear regression with a correlation coefficient of -0.995 between the average number of cycles to dislodge the crown and the taper. The slope was significantly different from zero (P=.0048), with a value of -7.58 and a standard error of 0.53. Conclusion: The number of cycles required to cause crown dislodgement was linear after 12 degrees in the resistive area and nearly zero for preparations in the nonresistive area. The limiting taper concept closely predicted the transition point where the slope of the graph of cycles to dislodgement as a function of taper abruptly changed.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 456-461 (6 pages)

Journal (Volume, Issue Number)

Journal of Prosthetic Dentistry (Volume 95, Issue 6)

Publication milestones

  • Published - 06/2006

Publication status

Published - 06/2006

ISSN

0022-3913

Publication IDs

  • Scopus: 33744916011
  • PubMed: 16765159

Publication metrics

Metrics

SciVal
citations
29
Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1
SciVal
FWCI
1.05
SciVal
Author count
5
SciVal
Paper percentile
79

PlumX, opens in new tab

Citation count
38
Captures
55