The impact of central lung distance, maximal heart distance, and radiation technique on the volumetric dose of the lung and heart for intact breast radiation.

  • Feng Ming Kong(corresponding author)
    ,
  • Eric E. Klein
    ,
  • Jeffrey D. Bradley
    ,
  • David B. Mansur
    ,
  • Marie E. Taylor
    ,
  • Carlos A. Perez
*Corresponding author for this work
Scholary Output:
Contribution to journal
Article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

PURPOSE: To investigate the impact of radiographic parameter and radiation technique on the volumetric dose of lung and heart for intact breast radiation. METHODS AND MATERIALS: Forty patients with both two-dimensional (2D) and computed tomographic (CT) simulations were enrolled in the study. Central lung distance (CLD), maximal heart distance (MHD), and maximal heart length (MHL) were measured under virtual simulation. Four plans were compared for each patient. Plan A used a traditional 2D tangential setup. Plan B used clinical target volume (CTV) based three-dimensional (3D) planning. Both plans C and D used a combination of a medial breast field with shallow tangents. Plan D is a further modification of plan C. RESULTS: Under the traditional tangential setup, the mean ipsilateral lung dose and volume at 20, 30, and 40 Gy correlated linearly with CLD (R = 0.85 approximately 0.91). The mean ipsilateral lung dose (Gy) approximated 4 times the CLD value (cm), whereas the percentage volume (%) of ipsilateral lung at 20, 30, and 40 Gy was about 10 times the CLD (cm). The mean heart dose and percentage volume at 20, 30, and 40 Gy correlated with MHD (R = 0.76 approximately 0.80) and MHL (R = 0.65 approximately 0.75). The mean heart dose (Gy) approximated 3 times the MHD value (cm), and the percentage volume (%) of the heart at 10, 20, 30, and 40 Gy was about 6 times MHD (cm). Radiation technique impacted lung and heart dose. The 3D tangential plan (plan B) failed to reduce the volumetric dose of lung and heart from that of the 2D plan (plan A). The medial breast techniques (plans C and D) significantly decreased the volume of lung and heart receiving high doses (30 and 40 Gy). Plan D further decreased the 20 Gy volumes. By use of the medial breast technique, the lung and heart dose were not impacted by original CLD and MHD/MHL. Therefore, the improvement from the tangential technique was more remarkable for patients with CLD >or= 3.0 cm (p < 0.001). CONCLUSIONS: The CLD and MHD impact the volumetric dose of lung and heart. The application of 3D planning for tangential breast irradiation does not decrease heart and lung dose. Adding a medial breast port significantly decreases percentage volume (PV) of lung and heart receiving high doses, especially when the CLD is excessive.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 963-971 (9 pages)

Journal (Volume, Issue Number)

International journal of radiation oncology, biology, physics (Volume 54, Issue 3)

Publication milestones

  • Published - 11/01/2002

Publication status

Published - 11/01/2002

ISSN

0360-3016

Publication IDs

  • Scopus: 0036835101
  • PubMed: 12377351

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
1.22
SciVal
Author count
8
SciVal
citations
72
SciVal
Paper percentile
90
SciVal
Top percentile
10
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
36
Citation count
101