Transfer function analysis of dynamic cerebral autoregulation in humans
- Rong Zhang,
- Julie H. Zuckerman,
- Cole A. Giller,
- Benjamin D. Levine(corresponding author)
- University of Texas at Dallas,
- Presbyterian Hospital of Dallas,
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewAbstract
<p>To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (V̇<sub>MCA</sub>) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure and V̇<sub>MCA</sub> were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes in V̇<sub>MCA</sub> during acute hypotension, which was compared with the directly measured change in V̇<sub>MCA</sub> during thigh cuff deflation. Beat-to-beat changes in V̇<sub>MCA</sub> occurred simultaneously with changes in arterial pressure, and the autospectrum of V̇<sub>MCA</sub> showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was >0.5 in the frequency range of 0.07-0.30 Hz and <0.5 at <0.07 Hz. Furthermore, the predicted change in V̇<sub>MCA</sub> was similar to the measured V̇<sub>MCA</sub> during thigh cuff deflation. These data suggest that spontaneous changes in V̇<sub>MCA</sub> that occur at the frequency range of 0.07-0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07-0.30 Hz.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages H233-41 (9 pages)Journal (Volume, Issue Number)
American Journal of Physiology - Heart and Circulatory Physiology (Volume 274, Issue 1 Pt 2)Publication milestones
- Published - 01/01/1998
Publication status
Published - 01/01/1998
ISSN
0363-6135Publication IDs
- Scopus: 33750854607
- PubMed: 9458872
Publication metrics
Metrics
SciVal
FWCI
3.84
SciVal
Author count
4
SciVal
citations
654
SciVal
Paper percentile
99
SciVal
Top percentile
1
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Mentions
1
Citation count
818
Captures
268
