Skip to search boxSkip to navigationSkip to main content

Ultrasound image transmission via camera phones for overreading

  • Michael Blaivas(corresponding author)
    ,
  • ,
  • Sandeep Duggal
*Corresponding author for this work
Scholary Output:
Contribution to journal
Article
Peer-review

Open access

Abstract

Emergency physicians using ultrasound frequently encounter unfamiliar findings during routine ultrasound examination. This is especially common for less experienced practitioners. Objective: To compare high-resolution thermal printer ultrasound images and images recorded and transmitted via commercial camera cell phones. Methods: This was a study comparing randomly selected images of actual ultrasound examinations performed in an academic level I ED with hospital-based emergency ultrasound credentialing. Two hospital credentialed emergency sonologists with extensive experience were asked to review 50 randomly selected images from actual patients as seen on a camera cell phone screen after being captured from a high-resolution thermal printout and sent to a similar phone. Reviewers recorded initial impression of the image and identified structures, measurements, and pathology. After hearing a brief clinical vignette, reviewer rated the images for image quality, detail, resolution, as previously defined, on a 10-point Likert scale. This process was then repeated with the original thermal printouts. Data were analyzed using descriptive statistics, agreement analysis, and the Student t test. Results: Reviewers showed good interrater agreement for pathology and structure detection between phone and thermal printer images. There was no statistically significant difference in image quality, resolution, and detail between phone images and thermal printer images. However, there was statistically significantly increase in confidence in diagnosis for reviewers when using thermal printer images as compared with phone images, P = .003 and P = .02. Several phone images were felt to be suboptimal, and there was moderate agreement on these between reviewers. Conclusions: Ultrasound pictures recorded by one phone and then sent to another yielded images that showed no statistically significant differences from traditional high-resolution thermal printouts in image quality, detail, and resolution. Measurements were too small to be read on the camera phones, and reviewers had statistically significantly lower confidence in their diagnosis when using the camera phones to review images.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 433-438 (6 pages)

Journal (Volume, Issue Number)

American Journal of Emergency Medicine (Volume 23, Issue 4)

Publication milestones

  • Published - 07/2005

Publication status

Published - 07/2005

ISSN

0735-6757

Publication IDs

  • Scopus: 22444434806
  • PubMed: 16032606

Publication metrics

Metrics

SciVal
FWCI
1.35
SciVal
Author count
3
SciVal
citations
28
SciVal
Paper percentile
78
Scopus
citations
Fractional count
1
Fractional count
0.33
Fractional count
2
Fractional count
0.67
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
49
Citation count
31