Localization of targets during stereotactic surgery is frequently accomplished by identification of the boundaries between the gray matter of various nuclei and the surrounding white matter. The authors describe an intracranial probe developed for this purpose, which uses near-infrared (NIR) light. The probe fits through standard stereotactic holders and emits light at its tip. The scattered light is detected and analyzed by a spectrometer, with the slope of the trailing portion of the reflectance curve used as the measurement value. Near-infrared readings were obtained during 27 neurosurgical procedures. The first three operations were temporal lobectomies, with values obtained from tracks in the resected specimen and resection bed. In the next five procedures, the probe was inserted stereotactically to a depth of 1 to 2 cm with measurements obtained every 1 mm. The probe was then used in 19 stereotactic procedures for movement disorders, obtaining measurements every 0.5 to 1 mm to target depths of 6 to 8 cm to interrogate subcortical structures. The NIR signals were correlated to distances beneath the cortical surface measured on postoperative computerized tomography or magnetic resonance imaging by using angle correction and three-dimensional reconstruction techniques. The NIR values for white and gray matter obtained during the lobectomies were significantly different (white matter 2.5 ± 0.37, gray matter 0.82 ± 0.23 mean ± standard deviation). The NIR values from the superficial stereotactic tracks showed initial low values corresponding to cortical gray matter and high values corresponding to subcortical white matter. There was good correlation between the NIR signals and postoperative imaging in the 19 stereotactic cases. Dips due to adjacent sulci, a plateau of high signal due to subcortical white matter, a dip in the NIR signal during passage through the ventricle, dips due to the caudate nucleus, and peaks due to the white matter capsule between ventricle and thalamus were constant features. The putamen-capsule boundary and the lamina externa and interna of the globus pallidus could be distinguished in three cases. Elevated signals corresponding to the thalamic floor were seen in 10 cases. Nuances such as prior lesions and nonspecific white matter changes were also detected. There was no incidence of morbidity associated with use of the probe. Data acquisition was straightforward and the equipment required for the studies was inexpensive. The NIR probe described in this article seems to be able to detect gray-white matter boundaries around and within subcortical structures commonly encountered in stereotactic functional neurosurgery. This simple, inexpensive method deserves further study to establish its efficacy for stereotactic localization.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 498-505 (8 pages)

Journal (Volume, Issue Number)

Journal of neurosurgery (Volume 93, Issue 3)

Publication milestones

  • Published - 01/01/2000

Publication status

Published - 01/01/2000

ISSN

0022-3085

Publication IDs

  • Scopus: 0033850424
  • PubMed: 10969953

Publication metrics

Metrics

SciVal
FWCI
1.59
SciVal
Author count
3
SciVal
citations
36
SciVal
Paper percentile
79
Scopus
citations
Fractional count
1
Fractional count
0.33
Fractional count
2
Fractional count
0.67
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Citation count
41
Captures
27