T1 - In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading
AU - Sananez, Andreina
AU - Lefebvre, Carol
AU - Looney, Stephen
AU - Baker, Philip S
AU - Mettenburg, Don
AU - Rueggeberg, Frederick A.
N1 - Publisher Copyright:
© 2015 Editorial Council for the Journal of Prosthetic Dentistry.
PY - 2015/5/1
Y1 - 2015/5/1
N2 - Statement of problem Clinicians question when to evaluate for worn or loose implant-supported retainer screws to prevent possible clinical complications. Purpose The purpose of this study was to compare differences among initial and postdynamically loaded detorque values and identify physical structural changes of prosthetic retaining screws in a simulated implant-supported mandibular complete fixed prosthesis. Material and methods Nine groups and nonloaded controls comprising a 5-implant-supported, milled titanium framework were fabricated and assembled (screw torque 35 Ncm). Dynamic loading (20 to 220 N) was applied to simulate 2 years of oral function. After testing, screw detorque values were measured (ΔT, initial-detorque value). A scanning electron microscopic analysis of screw threads was used to assess physical changes. Data were analyzed by 2-way ANOVA to determine the influence of loading and implant position on ΔT (α=.05). Results ΔT values of loaded and nonloaded groups were compared separately at each implant position and showed a significant difference only for the implant in the central position (P=.002). All positions were compared in terms of ΔT values separately for loaded and nonloaded conditions. A significantly higher ΔT was found in 1 cantilever area of the loaded group, whereas a significantly lower ΔT value was found in the central position in the nonloaded group. No statistically significant differences were found in physical changes between loading and nonloading or among implant positions. Conclusions When delivering a multiimplant supported prosthesis, the application of dynamic loading and the sequence in which implant screws are tightened could influence the subsequent detorque value of a screw; they have no effect on the physical appearance of screws after extended function.
AB - Statement of problem Clinicians question when to evaluate for worn or loose implant-supported retainer screws to prevent possible clinical complications. Purpose The purpose of this study was to compare differences among initial and postdynamically loaded detorque values and identify physical structural changes of prosthetic retaining screws in a simulated implant-supported mandibular complete fixed prosthesis. Material and methods Nine groups and nonloaded controls comprising a 5-implant-supported, milled titanium framework were fabricated and assembled (screw torque 35 Ncm). Dynamic loading (20 to 220 N) was applied to simulate 2 years of oral function. After testing, screw detorque values were measured (ΔT, initial-detorque value). A scanning electron microscopic analysis of screw threads was used to assess physical changes. Data were analyzed by 2-way ANOVA to determine the influence of loading and implant position on ΔT (α=.05). Results ΔT values of loaded and nonloaded groups were compared separately at each implant position and showed a significant difference only for the implant in the central position (P=.002). All positions were compared in terms of ΔT values separately for loaded and nonloaded conditions. A significantly higher ΔT was found in 1 cantilever area of the loaded group, whereas a significantly lower ΔT value was found in the central position in the nonloaded group. No statistically significant differences were found in physical changes between loading and nonloading or among implant positions. Conclusions When delivering a multiimplant supported prosthesis, the application of dynamic loading and the sequence in which implant screws are tightened could influence the subsequent detorque value of a screw; they have no effect on the physical appearance of screws after extended function.
UR - http://www.scopus.com/inward/record.url?scp=84929506967&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84929506967&partnerID=8YFLogxK
U2 - 10.1016/j.prosdent.2014.09.026
DO - 10.1016/j.prosdent.2014.09.026
M3 - Article
C2 - 25682530
AN - SCOPUS:84929506967
SN - 0022-3913
VL - 113
SP - 432
EP - 439
JO - Journal of Prosthetic Dentistry
JF - Journal of Prosthetic Dentistry
IS - 5
ER -