TY - JOUR
T1 - Shear bond strength characteristics on surface treatment modalities of CAD-CAM resin polymers
AU - Sinha, Nikita
AU - Thompson, Geoffrey A.
AU - Drago, Carl
AU - An, Hongseok
N1 - Publisher Copyright:
© 2023 by the American College of Prosthodontists.
PY - 2023
Y1 - 2023
N2 - Purpose: The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations. Material and Methods: A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica-modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil-free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples. The manufacturer's recommendations were followed for bonding composite resin to the samples with light-cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty-seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled. Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated. Statistical analysis was performed with post-hoc Tukey tests. Results: Statistical analysis revealed that there was a significant difference between the groups (p<0.001). The highest shear bond strengths were achieved for the specimens bonded with Visio.link without physical surface treatments (270.47 MPa). The lowest bond strengths were found for specimen surfaces abraded with 110 μm Al2O3 (117.03 Mpa). Conclusions: The results of this laboratory study indicated that the specimens used with Visio.link as provided by the manufacturer had the highest shear bond strengths between the composite resin and high-performance polymer test specimens. Modifications of the high-performance polymer surfaces with carbide burs did not change bonding strengths with the composite materials.
AB - Purpose: The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations. Material and Methods: A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica-modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil-free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples. The manufacturer's recommendations were followed for bonding composite resin to the samples with light-cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty-seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled. Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated. Statistical analysis was performed with post-hoc Tukey tests. Results: Statistical analysis revealed that there was a significant difference between the groups (p<0.001). The highest shear bond strengths were achieved for the specimens bonded with Visio.link without physical surface treatments (270.47 MPa). The lowest bond strengths were found for specimen surfaces abraded with 110 μm Al2O3 (117.03 Mpa). Conclusions: The results of this laboratory study indicated that the specimens used with Visio.link as provided by the manufacturer had the highest shear bond strengths between the composite resin and high-performance polymer test specimens. Modifications of the high-performance polymer surfaces with carbide burs did not change bonding strengths with the composite materials.
KW - bond strength
KW - high-performance polymers
KW - PEEK
KW - PEKKTON
KW - TRILOR
UR - http://www.scopus.com/inward/record.url?scp=85178201230&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85178201230&partnerID=8YFLogxK
U2 - 10.1111/jopr.13790
DO - 10.1111/jopr.13790
M3 - Review article
AN - SCOPUS:85178201230
SN - 1059-941X
JO - Journal of Prosthodontics
JF - Journal of Prosthodontics
ER -