<p>Objective Calculations of the left ventricular outflow tract (LVOT) area are typically based on the assumption that the LVOT is circular. This study was conducted to determine whether simultaneous orthogonal plane imaging with tilt during two-dimensional (2D) transesophageal echocardiography provided more accurate measurements of the LVOT area than the standard method. Design The authors prospectively measured the LVOT area in 2D by (1) the standard calculation based on the diameter as viewed on the long axis, and (2) a direct measurement using planimetry of the short axis, in consecutive patients presenting for elective surgery. The authors validated the planimetric technique by obtaining three-dimensional (3D) measurements in a subset of the subjects. Setting An academic medical center. Participants Adult surgical patients with no evidence of aortic stenosis. Interventions Transesophageal images were acquired by anesthesiologists certified by the National Board of Echocardiography. Measurements and Main Results Image acquisition and assessment were performed in the operating room and found to be adequate for analysis in 52 of 55 subjects. Simultaneous orthogonal plane imaging with tilt enabled long- and short-axis visualization of the LVOT. The authors found that the standard method underestimated the area by 0.78 cm<sup>2</sup> compared to the direct method (2D planimetry) when measured at the same beat at a similar point in the cardiac cycle. Moreover, 2D planimetry measurements were comparable to 3D planimetry measurements in the last 20 study subjects (R<sup>2</sup> = 0.88, p<0.0001). Conclusions This study suggested that 2D planimetry may be more accurate than 2D diameter-based calculations.</p>

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 1266-1271 (6 pages)

Journal (Volume, Issue Number)

Journal of Cardiothoracic and Vascular Anesthesia (Volume 30, Issue 5)

Publication milestones

  • Published - 10/01/2016

Publication status

Published - 10/01/2016

ISSN

1053-0770

Publication IDs

  • Scopus: 84991106961
  • PubMed: 27397861

Publication metrics

Metrics

SciVal
FWCI
0.13
SciVal
Author count
3
SciVal
citations
2
SciVal
Paper percentile
42
Scopus
citations
Fractional count
2
Fractional count
0.67
Fractional count
1
Fractional count
0.33
Fractional count
2
Fractional count
1

PlumX, opens in new tab

Captures
9
Citation count
2